Completed
-
Getting started with tank monitoring
-
Eastron energy meters manual
-
Setup Eastron SDM630MCT-MOD-MID
-
Setup Eastron SDM54-2T
-
Setup Eastron SDM120MOD 45A
-
Setting Eastron SDM630MCT-ML
-
Setting Eastron SDM630MCT-RC - 3F - Rogowski coil - Modbus - MID
-
Setup Eastron SDM630-MODBUS-MID-V2-3F/100A
-
Setup SDM230MOD – 100A – 1F – MID
-
Smart site cabin - troubleshooting
-
Smart Site Cabin- Installation Manual
-
Resetting the C04
-
Digital Matter Falcon - Installation tank monitoring
-
Smart site cabin - Use & set thermostat
-
Turning the heating on/off through the Calculus portal
-
Digital Matter Eagle manual
-
Digital Matter Hawk manual
-
Digital Matter Falcon connecting ratiometric sensor
-
Digital Matter Falcon manual
-
Calculus CO₂ measuring case manual
-
Restart and Calibration Elsys CO₂ sensor
-
Cabling NEN-EN-IEC 61439 standard
-
How to set a firing protocol?
-
How to install a tank monitor?
-
Reading Calculus gateway with the Calculus Digger tool
-
Calculus Digger tool manual
-
Reading out DSE controller with the Calculus Digger Tool
-
Monitoring well meter: setting limit and signal value
Introduction
Click on the "Edit" button in the top corner of the screen to edit your slide content.
Focal points
- Installation of the current transformer, P1 side toward the power supply.
- Attach the transformer with colson straps.
- Connect white wire/S1 of the transformer to the positive terminal of the energy meter.
- Connect black wire/S2 from the transformer to the negative terminal of the energy meter.
- Adjust for incorrect connection using energy meter settings.
- Check connection of the RJ12 cable on a three-phase transformer thoroughly, must click 2 times. See also the section RJ12 cable connection in Chapter 3 of this manual.
- Tighten the cables running through the transformer with cable spacers.
Types
Calculus offers the following Eastron meters:
- SDM120MOD Energymeter 45A - 1F - ModBus - MID
- SDM230MOD Energymeter 100A - 1F - ModBus - MID
- SDM630MCT - Modbus - MID - V2 - 3F/100A
- SDM630MCT - ML - 1L - MID - 3F - ModBus - 1xRJ12CT
- SDM630MCT - ML - 2L - MID - 3F - ModBus - 2xRJ12CT
- SDM630MCT - ML - 4L - MID - 3F - ModBus - 4xRJ12CT
- SDM630MCT - MODBUS - MID - 3F - CT
- SDM630MCT-RC - ModBus - Rogowski Coil - MID
- Eastron SDM72D-M-2-MID Energymeter - 3F - ModBus - MID
The type of energy meter is indicated above the energy meter display.
Information regarding the specifications such as, for example: 3x230/400V can be found below the display (see image above).
See also the manuals and data sheets attached.